Primary Care IT (PCIT) makes Nexus. As the manufacturer of software used in NHS care, we follow the clinical risk management standard DCB0129. We keep a hazard log: a list of the ways Nexus could contribute to harm, the controls we have built against each one, and how much risk is left.
This page summarises that log in plain English for practices, PCNs and ICBs. It covers every hazard on the log, including those still under review. Your clinical safety officer can ask us for the full entries (see Asking for the full entries).
*Last updated: 18 November 2026.*
What is yours and what is ours
- DCB0129 is ours. It covers the risks in how Nexus is designed and built. This page summarises it.
- DCB0160 is yours. It covers the risks in how your organisation deploys and uses Nexus. Each practice or organisation carries out its own DCB0160 assessment. We give you a deployment support pack to start from (see below).
Your clinical system stays the patient record. Nexus reads from it, and where your practice has switched it on, writes coded entries back to it.
Our Clinical Safety Officers
PCIT has two Clinical Safety Officers:
- Dustyn Saint is our internal Clinical Safety Officer, responsible for clinical risk management day to day: raising and assessing hazards, reviewing changes to Nexus, and handling safety reports.
- Imran Khan is our external Clinical Safety Officer, who reviews the hazard log independently every year and confirms hazards and their residual risk.
How to read the log
Status. Every hazard is either:
- Confirmed: a Clinical Safety Officer has reviewed the hazard and its controls and accepted the residual risk; or
- Under review: raised by our team and waiting for a Clinical Safety Officer. Its controls are in place, but the hazard is not signed off, and you should not treat it as signed off in your own safety case.
We do not publish a risk rating for a hazard until it is confirmed, so a rating is never quoted before a Clinical Safety Officer has agreed it.
Risk ratings. The log uses the standard DCB0129 five-by-five matrix: severity (minor to catastrophic) against likelihood (very low to very high). That gives a rating from 1 to 5:
| Rating | Meaning |
| 1 | Very low. Acceptable. |
| 2 | Low. Acceptable where further reduction is impractical. |
| 3 | Moderate. Accepted only with documented controls and Clinical Safety Officer agreement. |
| 4 | High. Must be reduced before release. |
| 5 | Very high. Unacceptable. |
References. Each hazard has a reference, NEX-H-001 onwards, numbered in the order it was raised. Numbers are never reused, so you can cite them in your own safety case.
Open actions. Where our own review has found a gap in a control, the full entry lists it as an open action, and we track it until it is closed.
The hazards at a glance
| Ref | Hazard | Area | Status |
| NEX-H-001 | Someone acts on information that is behind the patient record | Keeping information current | Confirmed, June 2026. Low, acceptable. Further controls added November 2026 are under review. |
| NEX-H-011 | A patient is invited repeatedly, too often, or for something already done | Contacting patients | Under review |
| NEX-H-012 | A patient who should not be contacted is contacted, or a message reaches the wrong person | Contacting patients | Under review |
| NEX-H-013 | An automation or bulk send goes to many patients in error, or with wrong content | Contacting patients | Under review |
| NEX-H-014 | A patient's reply or reading is not seen or acted on | Contacting patients | Under review |
| NEX-H-015 | A patient is wrongly left off, or put on, a worklist or monitoring list | Patient lists and clinical rules | Under review |
| NEX-H-016 | A wrong, duplicate or unconfirmed entry is written to the GP record | Writing to the record | Under review |
| NEX-H-018 | A clinical calculator gives a wrong result or files the wrong code | Writing to the record | Under review |
| NEX-H-017 | One patient's or practice's data is shown or acted on as another's | The right patient and practice | Under review |
| NEX-H-019 | Nexus or a data feed stops working and practices are not told | When something stops working | Under review |
| NEX-H-002 | The Practice assistant says an indicator is on pace, and recall for it is eased off | Practice assistant | Confirmed, November 2026. Acceptable. |
| NEX-H-003 | The Practice assistant gives a wrong or out-of-date figure | Practice assistant | Under review |
| NEX-H-004 | An answer from published national data is taken as the practice's own figures | Practice assistant, Ask AI | Under review |
| NEX-H-005 | The Practice assistant gives clinical advice or talks about a patient | Practice assistant | Under review |
| NEX-H-006 | An area not shared with the assistant looks like good performance | Practice assistant | Under review |
| NEX-H-007 | Text written to manipulate the assistant changes what it says | Practice assistant | Under review |
| NEX-H-008 | The Practice assistant stops working without anyone noticing | Practice assistant | Under review |
| NEX-H-009 | A wrong Local Enhanced Service (LES) search leads to wrong coding, a misinformed commissioner or a wrong payment | LES search packs | Under review |
| NEX-H-010 | An AI suggestion used in reviewing LES searches is wrong or incomplete, and the reviewer relies on it | LES search packs | Under review |
Keeping information current
NEX-H-001: acting on information that is behind the record
Status: confirmed, June 2026. Residual risk: low, acceptable. The further controls described below were recorded in November 2026 and are awaiting confirmation.
What could go wrong. A test result is in your clinical system but has not yet reached Nexus. A patient is prompted to book a test they have already had, a member of staff recalls someone who no longer needs it, or a practice works from figures without realising its overnight update has not arrived.
What we have done.
- The age of the data is on your dashboards. Your practice's dashboards show *Data to [date] · updated [time] ago*. It turns amber when one overnight update has been missed, and red, marked "delayed", when the data is more than 54 hours old. Where you are looking at several practices together, it shows the oldest.
- The live record is checked at the point of care. For Medicus practices, when a clinician has a patient open, the Nexus Chrome extension reads the patient's current record directly from Medicus (IM1 transactional), not from the overnight extract. Anything the live record shows was done since the extract is taken off that patient's list. The check is deliberately cautious: a result with no date, or dated the same day as the extract, does not hide anything, so a real recall is never hidden by mistake. The CQC actions dashboard confirms outstanding items against the live record in the same way.
- Invitations are remembered. Nexus keeps a record of every invitation sent to each patient, so a patient waiting for the record to catch up is not invited again. See NEX-H-011.
- Updates complete within 48 hours. We commit to bringing in a result within 48 hours of it appearing in your clinical system; most arrive overnight.
- A missing update is chased. We are alerted when a practice's data feed has not arrived for 48 hours, when an extract is incomplete, or when the overnight processing fails for a practice. A partly loaded extract is never applied.
- Patients can tell us. A patient can say "I've already had this" or "I've booked it", and the reminder pauses straight away. Reminders are not issued while the overnight processing is running.
- Items close only on a verified result, so information that is behind corrects itself on the next overnight run.
What you'll see. The data-age badge at the top of your dashboards. If it is red, the figures on that page are from the date it shows.
Contacting patients
These controls apply to everything Nexus sends to patients:
- Automated messages need clinical sign-off by our Clinical Safety Officer, then your practice must switch them on.
- Invitations, questionnaires and automated messages are checked at the moment of sending, not only when the list was made.
- Texts and emails carry no clinical detail. They say a message is waiting, and the patient confirms who they are before they can read it.
- Every message is recorded: what was sent, to whom, by whom and when.
NEX-H-011: repeated or unnecessary invitations
Status: under review. Not signed off.
What could go wrong. A patient is invited for the same thing more than once in a short time, more often than the programme intends, or for a test they have already had.
What we have done.
- Every invitation is logged against the patient. Automated invitations allow a set number of attempts, usually three, with a minimum gap between them. When they are used up, the patient is passed to your team, not sent more messages.
- A patient who already has a live invitation for something is not sent another for the same thing.
- A new contract year starts a fresh round of invitations, but still keeps the gap since the last message.
- Where it applies, an "invited" code is written to the record after a real send, so the history is in the clinical record too.
- A send that fails is not counted as sent, and a send that succeeded is not repeated.
- The invitation history is kept for longer than any of the gaps it enforces.
- At the point of care, Medicus practices check the live record first (see NEX-H-001).
NEX-H-012: contacting someone who should not be contacted
Status: under review. Not signed off.
What could go wrong. Nexus contacts a patient who has died, left the practice, opted out or is restricted, or a message reaches someone other than the patient.
What we have done.
- Patients who have died, left the practice or are not registered for general medical services are refused at the moment of sending.
- Opt-outs are checked before every invitation, questionnaire and automated message, on every channel. A patient can opt out by replying STOP, from the message page, or through their preferences.
- Restricted patients, and patients who have someone acting for them, are never sent links.
- Messages contain no clinical detail, and the patient must confirm their date of birth, surname and postcode to read one.
- If a recipient says a message is not for them, the link is cancelled, the number is opted out, and your team is given a task.
- A message that bounces stops further messages to that address, and your team is given a call or letter task instead.
NEX-H-013: an automation or bulk send goes wrong
Status: under review. Not signed off.
What could go wrong. An automation or bulk send goes to the wrong patients, to far more patients than intended, or with misleading wording.
What we have done.
- An automation cannot run until our Clinical Safety Officer has signed off it and its wording. Your practice must then switch it on. It starts in a trial mode that sends nothing, and an admin must accept it before it goes live. Changing its set-up puts it back into trial mode.
- Signed-off wording is locked. If it is edited, it stops sending.
- Sending is capped per practice per hour and per day, and per run, and only happens between 7am and 9pm.
- The patients come from the clinically signed-off lists (see NEX-H-015), and each one is re-checked at the moment of sending.
NEX-H-014: a patient's reply is not seen
Status: under review. Not signed off.
What could go wrong. A patient answers a questionnaire, sends in a reading or replies to a message, and nobody at the practice sees it in time.
What we have done.
- Every questionnaire answer goes to your practice inbox. If there is nowhere to send it, the answer is refused openly, never silently lost.
- A blood pressure of 180/120 or above, or a top reading of 90 or below, is marked urgent. The patient is told straight away what to do, and the item is raised to high priority in your inbox.
- If an inbox item is still unread after 72 hours, or sooner for high priority, your team is alerted. A queue with nobody reading it raises an alert at once.
- Implausible readings are held back rather than filed.
Patient lists and clinical rules
NEX-H-015: a patient wrongly left off, or put on, a list
Status: under review. Not signed off.
What could go wrong. A patient who needs monitoring or a review is missing from the list that should show them, for example a patient on a high-risk medicine who is due blood tests. Or a patient is on a list they should not be on, or a rule uses an out-of-date guideline.
What we have done.
- Drug and condition monitoring rules are clinically signed off. Only our Clinical Safety Officer can approve or change a rule. Each published set of rules is locked to that sign-off, and any change blocks publication until it is signed off again.
- Rules are checked against real patients. Before a rule is linked to a code list, the Clinical Safety Officer sees the actual patients it selects. A rule that selects nobody is refused.
- A new rule set cannot quietly drop monitoring. Publishing is refused if any rule that ran before would stop running.
- Guidance is watched every month. The BNF, NICE, CKS, SPS and gov.uk sections each rule is based on are checked monthly. A change triggers a clinical re-review.
- Practices cannot change safety intervals. The Clinical Safety Officer sets them.
- QOF lists follow the NHS England business rules. Every business rule is accounted for, test patients check every change, and new or revised rule documents are watched for. We are alerted if stored lists were built by an older version of our rules engine.
- Code-list releases are checked. When a national code-list release changes a list we use, the change must be signed off before it is used.
- Exclusions are recorded. Where a patient is excepted from a QOF indicator, the list records why.
- New work is safety-gated. A development change with clinical risk cannot be released until it has its own hazard assessment and Clinical Safety Officer sign-off.
Writing to the GP record
NEX-H-016: a wrong, duplicate or unconfirmed entry in the record
Status: under review. Not signed off.
What could go wrong. Nexus files an entry in the record that is wrong, filed twice or filed for the wrong patient, or reports an entry as filed when it was not.
What we have done.
- Entries Nexus files from its queues (QOF codes, blood pressure and other readings) count as filed only when the clinical system confirms them with its own reference.
- Failed entries are retried on a schedule. An entry the clinical system refuses is not retried, and is reported instead.
- Each pending entry can be queued only once, so a retry completes an entry rather than repeating it.
- Nothing is filed until the codes it uses have been clinically signed off. Each entry is re-checked against the current code lists, so a code retired at year end is not filed.
- Record and register codes need a named clinician. Calculator results need a clinician to confirm. Filing questionnaire answers automatically is off unless your practice chooses it.
- Anything that could not be filed is listed under Inbox → System alerts until it is in the record.
- Practices whose clinical system does not accept entries from Nexus are told which entries to code by hand.
NEX-H-018: a calculator gives a wrong result
Status: under review. Not signed off.
What could go wrong. A clinical calculator, such as CHA₂DS₂-VASc, returns a wrong score, or files its result under the wrong code.
What we have done.
- Missing inputs are shown, never assumed. Implausible values are left out of the score.
- Medication inputs always carry a completeness warning.
- Result codes are checked against the NHS terminology service before a calculator is approved.
- Changing a live calculator's code list sends it back for re-approval.
- Nothing is filed until a clinician confirms.
The right patient and the right practice
NEX-H-017: one patient's or practice's data shown as another's
Status: under review. Not signed off.
What could go wrong. A clinician sees or acts on another patient's or another practice's data, believing it is their own.
What we have done.
- Every request for patient data is checked against what you are allowed to see. If any part is not allowed, the whole request is refused rather than quietly cut down.
- Access needs two-factor sign-in, a current data sharing agreement and an approved role.
- Automated checks on every change to Nexus look for a page or query that could show the wrong organisation's data.
- Each patient has exactly one NHS number in Nexus.
- Pages show which practice you are looking at, and who you are signed in as.
- Restricted patients are left out of reports.
- Demonstration mode uses invented patients, with a banner on every page.
When something stops working
NEX-H-019: Nexus or a data feed stops and nobody is told
Status: under review. Not signed off.
What could go wrong. Nexus, a practice's data feed or a messaging service stops working, and lists stop updating or invitations stop going out without the practice noticing.
What we have done.
- The data-age badge on your dashboards turns amber, then red, when your updates stop arriving (see NEX-H-001).
- We are alerted when the platform is unhealthy (checked every 15 minutes), when a practice's feed is missing for 48 hours, when an extract is incomplete or stalled, and when overnight processing fails for a practice two nights running.
- Messages and record entries that fail are retried, and are not counted as done until they succeed.
The Practice assistant
The Practice assistant is the AI chat and the daily insight cards that answer questions about your practice's performance. It works from practice-level totals prepared overnight. It holds no patient-identifiable data, and it does not make decisions about patients.
These controls apply to all the Practice assistant hazards below:
- The assistant restates figures that Nexus has already worked out, using the same calculations as your dashboards. It is told never to work out figures of its own.
- Every figure carries the date it was prepared. Your dashboards stay the live view.
- Where a figure cannot be worked out, the assistant says so. It never shows it as zero.
- Before the assistant is switched on for a practice, we check its figures against that practice's dashboards. Any difference stops go-live.
- Only staff your practice admin chooses can use it.
NEX-H-002: "on pace" taken as "done"
Status: confirmed, November 2026. Residual risk: acceptable.
What could go wrong. The assistant says a QOF indicator is on pace for the year end. The team eases off recall for it, and the year end misses the threshold.
What we have done.
- Year-end projections come from the same calculation as your QOF dashboard, and automated tests check that the two match.
- The assistant never compares a figure with a threshold itself. It is given the answer ("on pace", "behind", "far behind").
- Every projection is worded "at the current pace, as of" a date, as an estimate, not a promise.
- Registers, which have no target to be on pace for, are never described as on or off pace.
What we are still doing. Sampling real answers during the pilot, and comparing projections with actual achievement at the 2026/27 year end.
NEX-H-003: a wrong or out-of-date figure
Status: under review. Not signed off.
What could go wrong. The assistant gives a figure that does not match your worklist, or an old figure with no date, and the team plans on it.
What we have done. The general controls above; insight cards regenerate when their date changes; we are alerted if the overnight preparation fails or comes back empty; answers about outstanding work link straight to the live worklist.
NEX-H-004: national data taken as your own
Status: under review. Not signed off.
What could go wrong. On one of your practice dashboards, Ask AI answers from published national data, and the answer is taken as your practice's figures now.
What we have done. When Ask AI answers from national data, a notice says so and why. Where the assistant uses both, it labels every figure as national or practice data with its period, and never combines them in one number.
What you'll see. A notice above the Ask AI answer whenever it is national data.
NEX-H-005: clinical advice or claims about a patient
Status: under review. Not signed off.
What could go wrong. The assistant gives clinical advice or says something about a named patient, and someone follows it.
What we have done. The assistant has no patient data, so it cannot know about an individual. NHS numbers, dates of birth, postcodes and names typed into a question are blocked before it goes anywhere, as are requests for patient lists. It is told not to give doses, drug choices, intervals, targets, diagnoses or any advice about a patient, and refers people to local protocols, the BNF, NICE and the record. The only links it can give are to Nexus worklists.
NEX-H-006: an area that isn't shared looks like good performance
Status: under review. Not signed off.
What could go wrong. An area kept from the assistant is left out of a "what to work on" list without saying so.
What we have done. The assistant knows how many areas it has not been given and says so, and never says there is no work in an area it can't see.
What you'll see. When any area is held back, the first insight card each day says how many, and points you to the dashboards. This text is added by Nexus itself, not the AI.
NEX-H-007: text written to manipulate the assistant
Status: under review. Not signed off.
What could go wrong. Text in a question, or on the page, is written to make the assistant ignore its rules.
What we have done. Questions, and whole conversations, are screened before the assistant sees them; if screening can't run, the question is refused. Page content and data are treated as information, never instructions. The assistant can only read your own practice's totals, cannot write anything, and cannot send you to an arbitrary link.
NEX-H-008: the assistant stops without anyone noticing
Status: under review. Not signed off.
What could go wrong. The morning insight card stops appearing, or an old one stays up, and nobody notices.
What we have done. We are alerted if the overnight preparation fails or comes back empty. If a safety check can't run, the assistant says it is briefly unavailable rather than answering without it. Dashboards and worklists work without the assistant.
What you'll see. Every card shows its date, so an old card shows its age.
Local Enhanced Service (LES) search packs
For some ICBs we review the searches practices use for a Local Enhanced Service, supply corrected EMIS search packs, and turn approved indicators into Nexus contract measures. These produce the lists practices work from, the achievement figures commissioners are briefed on, and, once promoted, payment figures.
NEX-H-009: a wrong LES search, or a wrong payment figure
Status: under review. Not signed off.
What could go wrong. A search pack does not match the LES specification, so a patient is coded wrongly, a commissioner is misinformed, or a promoted measure pays on the wrong patients or the wrong amount.
What we have done.
- Every logic correction must cite a confirmed clause of the specification.
- A pack, or a new contract measure made from it, must be approved by a clinician who did not build it.
- Every pack is imported into EMIS Web and checked against sample patients for each list before approval.
- "Possibly eligible" lists are labelled for clinical review, never as income, and must reach a confirmation rate at a pilot practice before wider release.
- Only the exact approved file can be installed at practices.
- A contract measure is built from the commissioner's own original search, not our corrected copy, so payment follows the scheme as written.
- Payment amounts are drafted only from confirmed payment clauses, and overwriting an existing amount needs a second person.
NEX-H-010: relying on an AI suggestion in LES review
Status: under review. Not signed off.
What could go wrong. When our team reviews LES searches, an AI tool suggests possible problems. A reviewer accepts a wrong suggestion or dismisses a real problem. This tool is used only by PCIT staff.
What we have done.
- A suggestion never becomes a finding by itself: a reviewer must accept it, or dismiss it with a reason. A search cannot be marked reviewed while any suggestion is undecided, or before the full checklist is complete.
- Suggestions that cite no precedent and no specification clause are dropped. The AI cannot mark anything critical.
- No patient-identifiable information is sent to the AI.
- A sample of searches, one in ten by default, is reviewed with the suggestions hidden, so the AI's hits and misses can be measured against independent reviewers.
- A new AI model or instruction set cannot be adopted until it has been tested against past cases and has done at least as well as the one before.
- A type of suggestion that reviewers keep rejecting is switched off automatically.
Your own assessment (DCB0160)
Your organisation is responsible for the clinical safety of how you deploy and use Nexus. For the Practice assistant we provide a deployment support pack listing the hazards your practice owns and the checks we suggest; you can take it as the starting point for your own hazard log. Ask support@primarycareit.co.uk for it.
When you cite our hazards in your safety case, use the references on this page and their current status. Don't treat a hazard marked under review as signed off.
Asking for the full entries
Each hazard has a full entry setting out the causes we considered, each control and how it is tested, the risk before and after controls, and any open actions. The Clinical Safety Officer or DPO of a practice, PCN or ICB can ask for the full entries, and for our clinical safety case, at support@primarycareit.co.uk.
Reporting a clinical safety concern
If you think Nexus has contributed to, or could contribute to, harm to a patient, tell us at support@primarycareit.co.uk with "Clinical safety" in the subject line. Include what you saw, where in Nexus, and when. Don't include patient-identifiable information in the email; we will tell you what we need and how to send it safely. Our internal Clinical Safety Officer reviews every report, and if a report shows a new hazard, we add it to the log.